Electronics Module, Data acquisition card, DMCA, PHOTON COUNTER
Product Introduction
Kinheng can provide scintillator detectors based on PMT, SiPM, PD for radiation spectrometer, personal dosimeter, security imaging and other fields.
1. SD series detector
2. ID series detector
3. Low energy X-ray detector
4. SiPM series detector
5. PD series detector
Products |
|||||
Series |
Model No. |
Description |
Input |
Output |
Connector |
PS |
PS-1 |
Electronic module with socket, 1”PMT |
14 Pins |
|
|
PS-2 |
Electronic module with socket& high/ low power supply-2”PMT |
14Pins |
|
|
|
SD |
SD-1 |
Detector. Integrated 1” NaI(Tl) and 1”PMT for Gamma ray |
|
14 Pins |
|
SD-2 |
Detector. Integrated 2” NaI(Tl) and 2”PMT for Gamma ray |
|
14Pins |
|
|
SD-2L |
Detector. Integrated 2L NaI(Tl) and 3”PMT for Gamma ray |
|
14 Pins |
|
|
SD-4L |
Detector. Integrated 4L NaI(Tl) and 3”PMT for Gamma ray |
|
14 Pins |
|
|
ID |
ID-1 |
Integrated Detector, with 1” NaI(Tl), PMT, electronics module for Gamma ray. |
|
|
GX16 |
ID-2 |
Integrated Detector, with 2” NaI(Tl), PMT, electronics module for Gamma ray. |
|
|
GX16 |
|
ID-2L |
Integrated Detector, with 2L NaI(Tl), PMT, electronics module for Gamma ray. |
|
|
GX16 |
|
ID-4L |
Integrated Detector, with 4L NaI(Tl), PMT, electronics module for Gamma ray. |
|
|
GX16 |
|
MCA |
MCA-1024 |
MCA, USB type-1024 Channel |
14 Pins |
|
|
MCA-2048 |
MCA, USB type-2048 Channel |
14Pins |
|
|
|
MCA-X |
MCA, GX16 type Connector-1024~32768 channels available |
14Pins |
|
|
|
HV |
H-1 |
HV Module |
|
|
|
HA-1 |
HV Adjustable Module |
|
|
|
|
HL-1 |
High/Low Voltage |
|
|
|
|
HLA-1 |
High/Low Adjustable Voltage |
|
|
|
|
X |
X-1 |
Integrated detector-X ray 1” Crystal |
|
|
GX16 |
S |
S-1 |
SIPM Integrated Detector |
|
|
GX16 |
S-2 |
SIPM Integrated Detector |
|
|
GX16 |
SD series detectors encapsulate crystal and PMT into one housing, which overcomes the hygroscopic disadvantage of some crystals including NaI(Tl), LaBr3:Ce, CLYC. When packaging PMT, internal geomagnetic shielding material reduced the influence of geomagnetic field on the detector. Applicable for pulse counting, energy spectrum measurement and radiation dose measurement.
PS-Plug Socket Module |
SD- Separated Detector |
ID-Integrated Detector |
H- High Voltage |
HL- Fixed High/Low Voltage |
AH- Adjustable High Voltage |
AHL- Adjustable High/Low Voltage |
MCA-Multi Channel Analyzer |
X-ray Detector |
S-SiPM Detector |
Properties
Model Properties |
PS-1 |
PS-2 |
PMT |
1” |
2”or above |
PMT Model |
CR125、CR284、CR332 |
CR173、CR119、CR160 |
Storage Temperature |
-55 ~ 70℃ |
-55 ~ 70℃ |
Operation Temperature |
-40~ 55℃ |
-40~ 55℃ |
HV |
0~+1250V |
None |
Low Voltage |
±5V |
+5V |
Signal Amplitude |
-1V |
-1V |
Signal Polarity |
Negative |
Negative |
Signal Baseline |
±20mV |
±20mV |
Signal Output Type |
Negative exponential decay pulse |
Negative exponential decay pulse |
Operation Humidity |
≤70% |
≤70% |
Application
1.PMT + Scintillator Assembly Signal Extraction
2.Detector testing
3.Spectrum analysis
Spectral analysis
Spectral analysis or spectrum analysis is analysis in terms of a spectrum of frequencies or related quantities such as energies, eigenvalues, etc. In specific areas it may refer to: Spectroscopy in chemistry and physics, a method of analyzing the properties of matter from their electromagnetic interactions.
Importance of the spectrum analyzers
Radio frequency (RF) signals and wireless communications are ubiquitous today thanks to Wi-Fi, mobile networking and communications, wireless internet of things device sensors, traditional radio, RADAR and more. To test and design such circuits and systems, it is useful to see the entire signal spectrum and other factors like spurious signals, noise, modulated signal width, etc.