PMT Separated Detector, PMT combined Scintillator Detector
Product Introduction
Kinheng can provide scintillator detectors based on PMT, SiPM, PD for radiation spectrometer, personal dosimeter, security imaging and other fields.
1. SD series detector
2. ID series detector
3. Low energy X-ray detector
4. SiPM series detector
5. PD series detector
Products |
|||||
Series |
Model No. |
Description |
Input |
Output |
Connector |
PS |
PS-1 |
Electronic module with socket, 1”PMT |
14 Pins |
|
|
PS-2 |
Electronic module with socket& high/ low power supply-2”PMT |
14Pins |
|
|
|
SD |
SD-1 |
Detector. Integrated 1” NaI(Tl) and 1”PMT for Gamma ray |
|
14 Pins |
|
SD-2 |
Detector. Integrated 2” NaI(Tl) and 2”PMT for Gamma ray |
|
14Pins |
|
|
SD-2L |
Detector. Integrated 2L NaI(Tl) and 3”PMT for Gamma ray |
|
14 Pins |
|
|
SD-4L |
Detector. Integrated 4L NaI(Tl) and 3”PMT for Gamma ray |
|
14 Pins |
|
|
ID |
ID-1 |
Integrated Detector, with 1” NaI(Tl), PMT, electronics module for Gamma ray. |
|
|
GX16 |
ID-2 |
Integrated Detector, with 2” NaI(Tl), PMT, electronics module for Gamma ray. |
|
|
GX16 |
|
ID-2L |
Integrated Detector, with 2L NaI(Tl), PMT, electronics module for Gamma ray. |
|
|
GX16 |
|
ID-4L |
Integrated Detector, with 4L NaI(Tl), PMT, electronics module for Gamma ray. |
|
|
GX16 |
|
MCA |
MCA-1024 |
MCA, USB type-1024 Channel |
14 Pins |
|
|
MCA-2048 |
MCA, USB type-2048 Channel |
14Pins |
|
|
|
MCA-X |
MCA, GX16 type Connector-1024~32768 channels available |
14Pins |
|
|
|
HV |
H-1 |
HV Module |
|
|
|
HA-1 |
HV Adjustable Module |
|
|
|
|
HL-1 |
High/Low Voltage |
|
|
|
|
HLA-1 |
High/Low Adjustable Voltage |
|
|
|
|
X |
X-1 |
Integrated detector-X ray 1” Crystal |
|
|
GX16 |
S |
S-1 |
SIPM Integrated Detector |
|
|
GX16 |
S-2 |
SIPM Integrated Detector |
|
|
GX16 |
SD series detectors encapsulate crystal and PMT into one housing, which overcomes the hygroscopic disadvantage of some crystals including NaI(Tl), LaBr3:Ce, CLYC. When packaging PMT, internal geomagnetic shielding material reduced the influence of geomagnetic field on the detector. Applicable for pulse counting, energy spectrum measurement and radiation dose measurement.
PS-Plug Socket Module |
SD- Separated Detector |
ID-Integrated Detector |
H- High Voltage |
HL- Fixed High/Low Voltage |
AH- Adjustable High Voltage |
AHL- Adjustable High/Low Voltage |
MCA-Multi Channel Analyzer |
X-ray Detector |
S-SiPM Detector |
2” Probe Dimension
Pin Definition
Properties
Model Properties |
SD-1 |
SD-2 |
SD-2L |
SD-4L |
Crystal Size | 1” | 2"&3“ | 50x100x400mm/100x100x200mm | 100x100x400mm |
PMT | CR125 | CR105, CR119 | CR119 | CR119 |
Storage Temperature | -20 ~ 70℃ | -20 ~ 70℃ | -20 ~ 70℃ | -20 ~ 70℃ |
Operation Temperature | 0~ 40℃ | 0~ 40℃ | 0~ 40℃ | 0~ 40℃ |
HV | 0~+1500V | 0~+1500V | 0~+1500V | 0~+1500V |
Scintillator | NaI(Tl), LaBr3, CeBr3 | NaI(Tl), LaBr3, CeBr3 | NaI(Tl), LaBr3, CeBr3 | NaI(Tl), LaBr3, CeBr3 |
Operation Humidity | ≤70% | ≤70% | ≤70% | ≤70% |
Energy Resolution | 6% ~ 8% | 6% ~ 8% | 7% ~ 8.5% | 7% ~ 8.5% |
Application
1. Radiation dose measurement
A dose of medical radiation is not like a dose of medicine. When it comes to radiation dose, there are different types of and units of measurement. Radiation dose is a complicated topic.
2. Energy measurement
Electrical energy is the product of electrical power and time, and it is measured in joules. It is defined as “1 joule of energy is equal to 1 watt of power is consumed for 1 second’’.
I.e. Energy and power are closely related. Electrical energy can be measured only when electrical power is known. So first, we understand electrical power
3. Spectrum analysis
Spectral analysis or spectrum analysis is analysis in terms of a spectrum of frequencies or related quantities such as energies, eigenvalues, etc. In specific areas it may refer to: Spectroscopy in chemistry and physics, a method of analyzing the properties of matter from their electromagnetic interactions.
4. Nuclide identification
Those radionuclide characteristics are activity, thermal power, neutron production rates, and photon release rates.